Difference between revisions of "How to Choose a Potentiostat"
| Line 103: | Line 103: | ||
| Typical Applications | | Typical Applications | ||
|| | || | ||
| − | * | + | * Compound characterization |
| − | * Electrolysis | + | * Electrolysis |
| − | * Analytical chemistry | + | * Analytical chemistry |
| − | * Kinetics | + | * Kinetics |
| − | * Sensors | + | * Sensors |
|| | || | ||
| − | * | + | * Compound characterization |
| − | * Electrolysis | + | * Electrolysis |
| − | * Analytical chemistry | + | * Analytical chemistry |
| − | * Kinetics | + | * Kinetics |
| − | * Sensors | + | * Sensors |
|| | || | ||
| − | * | + | * carbon fiber and ultramicroelectrodes |
* in vivo monitoring of dopamine | * in vivo monitoring of dopamine | ||
| − | * | + | * ionic transport across membranes or immiscible interfaces |
| − | * Monitor dissolved oxygen, nitric oxide, | + | * Monitor dissolved oxygen, nitric oxide, etc. |
|| | || | ||
| − | * Simultaneous monitoring of sensors | + | * Simultaneous monitoring of sensors |
| − | * Bipotentiostat operation | + | * Bipotentiostat operation |
| − | + | * Neurochemistry | |
| − | * Neurochemistry | + | |
|| | || | ||
* surface corrosion | * surface corrosion | ||
| Line 131: | Line 130: | ||
* epitaxial layers | * epitaxial layers | ||
* interfacial ion transport | * interfacial ion transport | ||
| − | * battery and fuel cell | + | * battery and fuel cell |
* biocompatible surfaces | * biocompatible surfaces | ||
|- | |- | ||
| Example || Example || Example || Example || Example || Example | | Example || Example || Example || Example || Example || Example | ||
|} | |} | ||
Revision as of 19:19, 9 May 2013
| Name | EChem Startup System | EChem Startup System with Fast Potentiostat | Dual Picostat System | QuadStat EChem System bundle | Advanced Electrochemistry System |
|---|---|---|---|---|---|
| Product Code | ER461 | ER461b | ER461p | ER864 | ERZ101 |
| Includes Products |
|
|
|
|
|
| Number of Channels | 1 | 1 | 2 (bipotentiostat) | 4 (quadpotentiostat) | 1 |
| Modes |
|
|
|
|
|
| Current Ranges |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±10, 5, 2, 1 µA ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA ±500, 200, 100, 50, 20, 10, 5, 2, 1 pA |
±1 mA* ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA* ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA* ±500, 200 pA*
|
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
| Electrochemistry Techniques |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
EIS Electrochemical Impedance Spectroscopy (potentiostatic and galvanostatic) CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
| Typical Applications |
|
|
|
|
|
| Example | Example | Example | Example | Example | Example |