Difference between revisions of "How to Choose a Potentiostat"
Line 144: | Line 144: | ||
|} | |} | ||
− | '''Electrochemistry Techniques | + | '''Acronyms for Electrochemistry Techniques''' |
+ | |||
+ | CV cyclic voltammetry; LSV linear sweep voltammetry; DPV differential pulse voltammetry; SWV square wave voltammetry; NPV normal pulse voltammetry; RPV reverse pulse voltammetry; LSSV linear sweep stripping voltammetry; DPSV differential pulse stripping voltammetry; SWSV square wave stripping voltammetry; NPSV normal pulse stripping voltammetry; MPV multipulse voltammetry; DPA differential pulse amperometry and double pulse amperometry; CPE constant potential electrolysis, DNPV differential normal pulse amperometry; DPV double pulse voltammetry; | ||
− | |||
CNA Chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; | CNA Chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; | ||
CPE controlled potential electrolysis; CCE controlled current electrolysis; RDE rotating disk* electrode; QCM quartz crystal microbalance* | CPE controlled potential electrolysis; CCE controlled current electrolysis; RDE rotating disk* electrode; QCM quartz crystal microbalance* | ||
RDE and QCM require additional third party equipment* | RDE and QCM require additional third party equipment* |
Revision as of 19:05, 16 May 2013
Name | |||||
---|---|---|---|---|---|
Product Code | ER461 | ER461b | ER461p | ER864 | ERZ101 |
Products Included |
|
|
|
|
|
Number of Channels | 1 | 1 | 2 (bipotentiostat) | 4 (quadpotentiostat) | 1 |
Modes |
|
|
|
|
|
Current Ranges |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±10, 5, 2, 1 µA ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA ±500, 200, 100, 50, 20, 10, 5, 2, 1 pA |
±1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA ±500, 200 pA x10 for high current model |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
Electrochemistry Techniques |
|
|
|
|
|
Typical Applications |
|
|
|
|
|
Acronyms for Electrochemistry Techniques
CV cyclic voltammetry; LSV linear sweep voltammetry; DPV differential pulse voltammetry; SWV square wave voltammetry; NPV normal pulse voltammetry; RPV reverse pulse voltammetry; LSSV linear sweep stripping voltammetry; DPSV differential pulse stripping voltammetry; SWSV square wave stripping voltammetry; NPSV normal pulse stripping voltammetry; MPV multipulse voltammetry; DPA differential pulse amperometry and double pulse amperometry; CPE constant potential electrolysis, DNPV differential normal pulse amperometry; DPV double pulse voltammetry;
CNA Chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; CPE controlled potential electrolysis; CCE controlled current electrolysis; RDE rotating disk* electrode; QCM quartz crystal microbalance*
RDE and QCM require additional third party equipment*