Difference between revisions of "How to Choose a Potentiostat"
Line 1: | Line 1: | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | ! Name !! [http://www.edaq.com/product_details_page.php?product_no=ER461 EChem Startup System] !! [http://www.edaq.com/product_details_page.php?product_no=EA163 EChem Startup System with Fast Potentiostat] !! [http://www.edaq.com/product_details_page.php?product_no=EA362 Dual Picostat System] !! QuadStat EChem System bundle !! Advanced Electrochemistry System | + | ! Name |
+ | !! | ||
+ | [http://www.edaq.com/product_details_page.php?product_no=ER461 EChem Startup System] | ||
+ | !! | ||
+ | [http://www.edaq.com/product_details_page.php?product_no=EA163 EChem Startup System with Fast Potentiostat] | ||
+ | !! | ||
+ | [http://www.edaq.com/product_details_page.php?product_no=EA362 Dual Picostat System] | ||
+ | !! | ||
+ | [http://www.edaq.com/product_details_page.php?product_no=EA164 QuadStat EChem System bundle] | ||
+ | !! | ||
+ | [http://www.edaq.com/product_details_page.php?product_no=ERZ101 Advanced Electrochemistry System] | ||
|- | |- | ||
| Product Code || ER461 || ER461b || ER461p || ER864 || ERZ101 | | Product Code || ER461 || ER461b || ER461p || ER864 || ERZ101 |
Revision as of 18:25, 9 May 2013
Name | ! | ! | ! | ! | ! |
---|---|---|---|---|---|
Product Code | ER461 | ER461b | ER461p | ER864 | ERZ101 |
Includes Products |
|
|
|
|
|
Number of Channels | 1 | 1 | 2 (bipotentiostat) | 4 (quadpotentiostat) | 1 |
Modes |
|
|
|
|
|
Current Ranges |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
±10, 5, 2, 1 µA ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA ±500, 200, 100, 50, 20, 10, 5, 2, 1 pA |
±1 mA* ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA* ±500, 200, 100, 50, 20, 10, 5, 2, 1 nA* ±500, 200 pA*
|
±100, 50, 20, 10, 5, 2, 1 mA ±500, 200, 100, 50, 20, 10, 5, 2, 1 µA ±500, 200, 100, 50, 20 nA |
Electrochemistry Techniques |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
EIS Electrochemical Impedance Spectroscopy (potentiostatic and galvanostatic) CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV,DPA, CPE, DNPV, DPV Chronoamperometry, chronocoulometry, chronopotentiometry, CPE, CCE, electrosynthesis, RDE*, QCM* |
Typical Applications |
|
|
|
|
|
Example | Example | Example | Example | Example | Example |