Line 106: | Line 106: | ||
| Electrochemistry Techniques | | Electrochemistry Techniques | ||
|| | || | ||
− | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, | + | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV |
CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | ||
|| | || | ||
− | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, | + | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV |
CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | ||
|| | || | ||
− | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, | + | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV |
CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | ||
|| | || | ||
Line 121: | Line 121: | ||
EIS Electrochemical Impedance Spectroscopy | EIS Electrochemical Impedance Spectroscopy | ||
− | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, | + | CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV |
CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* | ||
|- valign="top" | |- valign="top" | ||
Line 159: | Line 159: | ||
'''Acronyms for Electrochemistry Techniques''' | '''Acronyms for Electrochemistry Techniques''' | ||
− | CV cyclic voltammetry; LSV linear sweep voltammetry; DPV differential pulse voltammetry; SWV square wave voltammetry; NPV normal pulse voltammetry; RPV reverse pulse voltammetry; LSSV linear sweep stripping voltammetry; DPSV differential pulse stripping voltammetry; SWSV square wave stripping voltammetry; NPSV normal pulse stripping voltammetry; MPV multipulse voltammetry; DPA differential pulse amperometry and double pulse amperometry; CPE constant potential electrolysis, DNPV differential normal pulse amperometry; | + | CV cyclic voltammetry; LSV linear sweep voltammetry; DPV differential pulse voltammetry; SWV square wave voltammetry; NPV normal pulse voltammetry; RPV reverse pulse voltammetry; LSSV linear sweep stripping voltammetry; DPSV differential pulse stripping voltammetry; SWSV square wave stripping voltammetry; NPSV normal pulse stripping voltammetry; MPV multipulse voltammetry; DPA differential pulse amperometry and double pulse amperometry; CPE constant potential electrolysis, DNPV differential normal pulse amperometry; DBPV double pulse voltammetry; |
CNA chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; | CNA chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; |
Revision as of 13:55, 29 August 2013
Name | EChem Startup System | EChem Startup System with Fast Potentiostat | Dual Picostat Bundle | QuadStat EChem System Bundle | Advanced Electrochemistry System |
---|---|---|---|---|---|
Product Code | ER461 | ER7163 | ER7162 | ER864 | ERZ101 |
Products Included | |||||
Number of Channels | 1 | 1 | 2 (bipotentiostat) | 4 (quadpotentiostat) | 1 |
Modes |
|
|
|
|
|
Current Ranges |
±100, 50, 20, 10, 5, 2, 1 mA ±500,200,100,50,20,10,5,2,1 µA ±500, 200, 100, 50, 20 nA |
±100, 50, 20, 10, 5, 2, 1 mA ±500,200,100,50,20,10,5,2,1 µA ±500, 200, 100, 50, 20 nA |
±10, 5, 2, 1 µA ±500,200,100,50,20,10,5,2,1 nA ±500,200,100,50,20,10,5,2,1 pA |
±1 mA ±500,200,100,50,20,10,5,2,1 µA ±500,200,100,50,20,10,5,2,1 nA ±500, 200 pA (all x10 for high current model) |
±100, 50, 20, 10, 5, 2, 1 mA ±500,200,100,50,20,10,5,2,1 µA ±500, 200, 100, 50, 20 nA |
Electrochemistry Techniques |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* |
CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* |
CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* CV and LSV with Chart software |
EIS Electrochemical Impedance Spectroscopy CV, LSV, DPV, SWV, NPV, RPV, LSSV, DPSV, SWSV, NPSV, MPV, DPA, CPE, DNPV, DBPV CNA, CNC, CNP, CPE, CCE, electrosynthesis, RDE*, QCM* |
Typical Applications |
|
|
|
|
|
Acronyms for Electrochemistry Techniques
CV cyclic voltammetry; LSV linear sweep voltammetry; DPV differential pulse voltammetry; SWV square wave voltammetry; NPV normal pulse voltammetry; RPV reverse pulse voltammetry; LSSV linear sweep stripping voltammetry; DPSV differential pulse stripping voltammetry; SWSV square wave stripping voltammetry; NPSV normal pulse stripping voltammetry; MPV multipulse voltammetry; DPA differential pulse amperometry and double pulse amperometry; CPE constant potential electrolysis, DNPV differential normal pulse amperometry; DBPV double pulse voltammetry;
CNA chronoamperometry; CNC chronocoulometry; CNP chronopotentiometry; CPE controlled potential electrolysis; CCE controlled current electrolysis; RDE rotating disk electrode*; QCM quartz crystal microbalance*
RDE and QCM require additional third party equipment*