Voltammetric techniques that require the current signal to be plotted versus potential most commonly use the EChem software. Techniques requiring that the current or potential signal be plotted versus time are typically performed with the Chart software. This table indicates which software is better suited for a particular technique.
+
Voltammetric techniques that require the current signal to be plotted versus potential most commonly use the [http://www.edaq.com/product_details_page.php?product_no=ES260 EChem Software].  
 +
 
 +
Techniques requiring that the current or potential signal be plotted versus time are typically performed with the [http://www.edaq.com/product_details_page.php?product_no=ES500 Chart Software].  
 +
 
 +
This table indicates which software is better suited for a particular technique.
 +
 
  
 
{| class="wikitable"
 
{| class="wikitable"
 
|-
 
|-
! Electrochemistry Technique !! EChem Software !! Chart Software
+
! width="400pt" | Electrochemistry Technique !! EChem Software !! Chart Software
 +
|-
 +
| linear sweep voltammetry || style="text-align: center;" | ♦ ||
 +
|-
 +
| - potentiodynamic polarization || style="text-align: center;" | ♦ ||
 +
|-
 +
| - polarization resistance || style="text-align: center;" | ♦ ||
 +
|-
 +
| - IV curve of a solar cell || style="text-align: center;" | ♦ ||
 +
|-
 +
| differential pulse voltammetry || style="text-align: center;" | ♦ ||
 
|-
 
|-
| linear sweep voltammetry || style="text-align: center;" | * ||  
+
| square wave voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| potentiodynamic polarization || style="text-align: center;" | * ||  
+
| normal (and reverse) pulse voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| polarization resistance || style="text-align: center;" | * ||  
+
| linear sweep stripping voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| differential pulse voltammetry || style="text-align: center;" | * ||  
+
| differential pulse stripping voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| square wave voltammetry || style="text-align: center;" | * ||  
+
| square wave stripping voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| normal (and reverse) pulse voltammetry || style="text-align: center;" | * ||  
+
| normal pulse stripping voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| linear sweep stripping voltammetry || style="text-align: center;" | * ||  
+
| [https://www.edaq.com/wiki/Cyclic_Voltammetry:_Hints_and_Tips cyclic voltammetry] || style="text-align: center;" | ||  
 
|-
 
|-
| differential pulse stripping voltammetry || style="text-align: center;" | * ||  
+
| - cyclic potentiodynamic polarization scanning || style="text-align: center;" | ||  
 
|-
 
|-
| square wave stripping voltammetry || style="text-align: center;" | * ||  
+
| multipulse voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| normal pulse stripping voltammetry || style="text-align: center;" | * ||  
+
| - non-standard sampling for linear sweep voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| cyclic voltammetry || style="text-align: center;" | * ||  
+
| - non-standard sampling for cyclic voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| cyclic potentiodynamic polarization scanning || style="text-align: center;" | * ||  
+
| - cyclic square wave voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| multipulse voltammetry || style="text-align: center;" | * ||  
+
| - cyclic differential pulse voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| non-standard sampling for linear sweep voltammetry || style="text-align: center;" | * ||  
+
| pulse amperometry || style="text-align: center;" | ||  
 
|-
 
|-
| non-standard sampling for cyclic voltammetry || style="text-align: center;" | * ||  
+
| - differential pulse amperometry || style="text-align: center;" | ||  
 
|-
 
|-
| cyclic square wave voltammetry || style="text-align: center;" | * ||  
+
| - double pulse amperometry || style="text-align: center;" | ||  
 
|-
 
|-
| cyclic differential pulse voltammetry || style="text-align: center;" | * ||  
+
| - constant potential electrolysis || style="text-align: center;" | ||  
 
|-
 
|-
| pulse amperometry || style="text-align: center;" | * ||  
+
| - differential normal pulse voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| differential pulse amperometry || style="text-align: center;" | * ||  
+
| - double pulse voltammetry || style="text-align: center;" | ||  
 
|-
 
|-
| double pulse amperometry || style="text-align: center;" | * ||
+
| chronoamperometry || || style="text-align: center;" |
 
|-
 
|-
| constant potential electrolysis || style="text-align: center;" | * ||
+
| chronocoulometry || || style="text-align: center;" |
 
|-
 
|-
| differential normal pulse voltammetry || style="text-align: center;" | * ||
+
| chronopotentiometry || || style="text-align: center;" |
 
|-
 
|-
| double pulse voltammetry || style="text-align: center;" | * ||
+
| [https://www.edaq.com/wiki/Potentiometric_Stripping_Analysis_(PSA) potentiometric stripping analysis] || || style="text-align: center;" |
 
|-
 
|-
| chronoamperometry || || style="text-align: center;" | *
+
| controlled potential electrolysis || || style="text-align: center;" |
 
|-
 
|-
| chronocoulometry || || style="text-align: center;" | *
+
| controlled current electrolysis || || style="text-align: center;" |
 
|-
 
|-
| chronopotentiometry || || style="text-align: center;" | *
+
| battery charge-discharge (galvanostatic and potentiostatic) || || style="text-align: center;" |
 
|-
 
|-
| controlled potential electrolysis || || style="text-align: center;" | *
+
| electrosynthesis || style="text-align: center;" | ♦ || style="text-align: center;" |
 
|-
 
|-
| controlled current electrolysis || || style="text-align: center;" | *
+
| rotating ring disk electrodes * || || style="text-align: center;" |
 
|-
 
|-
| electrosynthesis || || style="text-align: center;" | *
+
| [https://www.edaq.com/wiki/Using_the_SRS_QCM200_Quartz_Crystal_Microbalance_with_an_e-corder quartz crystal microbalance] * || || style="text-align: center;" |
 
|-
 
|-
| rotating ring disk electrodes * || || style="text-align: center;" | *
+
| amperometric detection (for chromatography) || || style="text-align: center;" |
 
|-
 
|-
| quartz crystal microbalance * || || style="text-align: center;" | *
+
| monitoring of meters for biosensors, pH and ion selective electrodes, conductivity electrodes and dO2 sensors * || || style="text-align: center;" |
 
|-
 
|-
| amperometric detection (for chromatography) || || style="text-align: center;" | *
+
| [https://www.edaq.com/wiki/Using_the_eDAQ_Potentiostat_in_Galvanostat_Mode galvanostat mode] || || style="text-align: center;" |
 
|-
 
|-
| monitoring of meters for biosensors, ph and ion selective electrodes, conductivity electrodes and do2 sensors * || || style="text-align: center;" | *
+
| open circuit potential / open circuit voltage / high impedance voltmeter || || style="text-align: center;" |
 
|-
 
|-
 +
| closed circuit current / zero resistance ammeter || || style="text-align: center;" | ♦
 
|}
 
|}
  
 
Additional third party equipment required *
 
Additional third party equipment required *

Latest revision as of 16:17, 29 July 2019

Voltammetric techniques that require the current signal to be plotted versus potential most commonly use the EChem Software.

Techniques requiring that the current or potential signal be plotted versus time are typically performed with the Chart Software.

This table indicates which software is better suited for a particular technique.


Electrochemistry Technique EChem Software Chart Software
linear sweep voltammetry
- potentiodynamic polarization
- polarization resistance
- IV curve of a solar cell
differential pulse voltammetry
square wave voltammetry
normal (and reverse) pulse voltammetry
linear sweep stripping voltammetry
differential pulse stripping voltammetry
square wave stripping voltammetry
normal pulse stripping voltammetry
cyclic voltammetry
- cyclic potentiodynamic polarization scanning
multipulse voltammetry
- non-standard sampling for linear sweep voltammetry
- non-standard sampling for cyclic voltammetry
- cyclic square wave voltammetry
- cyclic differential pulse voltammetry
pulse amperometry
- differential pulse amperometry
- double pulse amperometry
- constant potential electrolysis
- differential normal pulse voltammetry
- double pulse voltammetry
chronoamperometry
chronocoulometry
chronopotentiometry
potentiometric stripping analysis
controlled potential electrolysis
controlled current electrolysis
battery charge-discharge (galvanostatic and potentiostatic)
electrosynthesis
rotating ring disk electrodes *
quartz crystal microbalance *
amperometric detection (for chromatography)
monitoring of meters for biosensors, pH and ion selective electrodes, conductivity electrodes and dO2 sensors *
galvanostat mode
open circuit potential / open circuit voltage / high impedance voltmeter
closed circuit current / zero resistance ammeter

Additional third party equipment required *