eDAQ News

subscribe to eDAQ news subscribe to eDAQ news updates

Zive SP1 Potentiostat available
An economic high quality potentiostat/ galvanostat/ impedance analyzer especially for electrochemical experiments with batteries, fuel cells, solar cells, corrosion samples and corrosion, and electrochemical sensors. The Zive SP1 Potentiostat is supplied with software packages for different types of experiment and connects to a Windows XP or later computer via USB. Handles currents of up to 1 amp to a maximum of 10 V but weighs only 2 kg. Impedance meanurements can be made between 10 µHz and 1 MHz.
(7 May, 2013)

ER167 New Dual Reference Adaptor released
The Dual Reference Adaptor allows two reference electrodes to be connected to the single reference electrode input of a potentiostat. Ideal for trans-membrane and ITES (interface of two immiscible electrolyte solutions) experiments.
(13 Aug, 2012)

New Pod-Vu release
A new version of Pod-Vu software is now available which features signal inversion on our amperometric dO2, Nitric Oxide, and Biosensor isoPods. This is useful for customers who want the raw current signals to rise and fall in the same direction as the substrate concentration.
(2 Aug, 2012)

Tethered Membranes Presentation
Dr Bruce Cornell, the inventor of our tethaPod and tethaPatch systems, will be making a presentation entitled "Ligand and Voltage Gated Ion Channel Measurements in Tethered Membranes" at IICC - International Ion Channel Conference: The New World of Anion and Cation Channels, in Jeju Korea, August 23-27
(27 Jun, 2012)

EA362 Dual Picostat
The eDAQ EA162 Picostat, high sensitivity potentiostat, has been superseded by the new EA362 Dual Picostat. The new Dual Picostat features improved sensitivity, and a bipotentiostat mode whereby two current signals can be monitored simultaneously from two working electrodes at disparate locations in the sample. There is also a new current signal offset capability to remove background signals so that signal changes can be recorded at higher sensitivities. This new unit is also electrically isolated and so is resistant to interference from neural stimulators, and ground loops.
(17 May, 2012)

New revision of EA164 QuadStat
The EA164 QuadStat, four channel potentiostat, has been re-released. This new revision features more range settings (from 20 pA to 10 mA) and a zero resistance ammeter operating mode available on each of its four channels. Now better value than ever!
(10 May, 2012)

Tethered membranes
Today eDAQ released its range of tethered membrane products. Tethered membranes are artificial planar phospholipid bilayers chemically bonded to a gold electrode by a series of molecular tethers. These membranes can house purified membrane proteins that form ion channels making them suitable for a number of studies including continuous membrane conduction monitoring, and electrochemical pulse techniques analogous to whole cell patch clamping. The speed and ease of experimentation using tethered membranes makes them ideal for pharmaceutical drug screening programs, as well as more fundamental ion channel investigations. Products include: SDx-R1 tethaPod; SDx-R2 tethaPatch, and SDx-T10 tethaPlate. More details at http://www.edaq.com/sdx1.php
(1 Feb, 2012)

Pod-Vu software released
Pod-Vu software is designed to work with up to eight eDAQ USB isoPods to record and display signals such as pH, dissolved oxygen, nitric oxide, solution conductivity, temperature, and oxidation/reduction potential. The software automatically recognises the isoPods and allows for the calibration of sensors. isoPods are individually electrically isolated so that cross talk and interference is minimised, and are connected directly to the USB ports of a computer or via a USB hub.
(1 Jul, 2011)

Waveform Generator for electrochemistry
The ER175 Waveform Generator is especially designed for electrochemistry experiments and produces pulses, ramps, as well as triangular and sinusoidal signals. Triangular waveforms can be started anywhere between their upper and lower limits. Ramps can be paused at their instantaneous values, or reversed mid scan. Highly stable low speed ramps are particularly useful for corrosion experiments, or solid state electrochemistry.
(1 Dec, 2010)

New EA466 Integrated Potentiostat System
The new eDAQ ER466 Potentiostat has been released. This is our first integrated potentiostat where data acquisition, waveform generation and potentiostat functionality are all included in the one compact box that simplifing setup an usage. Two general purpose signal inputs are included for extraneous signals.
(5 Nov, 2010)

New EA163 Potentiostat
The EA163 Potentiostat has been introduced to update our venerable EA161 Poteniostat. The EA163 has an extended bandwidth range (now to 100 kHz) making it suitable for use with the Z100 Electrochemical Impedance Analyser, while still being capable of most analytical electrochemical techniques.
(14 Sep, 2010)

Z100 Electrochemical Impedance Analyzer
Our new Z100 mid-range electrochemical impedance analyzer is designed for use with the eDAQ 163 Potentiostat. It caters for impedance experiments up to 100 kHz for and solid state physicists, corrosion engineers, chemists studying biosensors and surfaces, and fuel cell and battery scientists.
(13 Sep, 2010)

High voltage power supply for microchip electrophoresis
The ER230 HV Sequencer is a newly released dual channel high voltage power supply designed for use with microfluidic chips for chip electrophosesis, electrokinetic chromatography, or as a voltage source for EOF pumps.
(10 Sep, 2010)

Polarographic Oxygen Electrode
eDAQ has released a new polarographic (Clark style) oxygen electrode for chemical or biological applications.
(10 Sep, 2010)

New range of conductivity probes
Our new conductivity probes offer proven platinum plate reliability in various sensitivities (k = 0.1, 1 and 10)
(8 Sep, 2010)

Kanichi range of screen printed electrodes
Kanichi screen printed electrodes are available in plain carbon or impregnated with metal oxides. The BiO electrode can be used for anodic stripping voltammetry (ASV) in place of a conventional mercury electrode.
(5 Aug, 2010)

USB isoPods for pH, dO2, NO, temperature, conductivity
New USB isoPods connect directly to you PC via USB and use a serial (RS232) communications protocol and so be be used with LabVIEW or other serial compatible software. Electrical isolation ensures minimal noise and crosstalk.
(1 Aug, 2010)

Electrochemical disk electrodes
Platinum, gold, glassy carbon, and copper disk electrode, are now available singly or in discounted three packs for voltammetric and amperometric experiments.
(1 Aug, 2010)

New Leakless Reference Electrode
An all plastic leakless Ag/AgCl reference electrode suitable for electrochemistry research and teaching. The ET069 electrode is completely leakless and will not contaminate your sample with chloride or silver ions.
(1 Jul, 2010)

Subscribe to our Screencasts Podcast
Screencasts are small how-to movies giving instruction on setting up eDAQ equipment and software, and with calibrations and analysis of data. You can now subscribe to our screencasts podcast on our screencasts page
(10 Jun, 2010)

isoPods for pH, dO2, NO, temperature, conductivity
These electrically isolated versions supersede our range miniature Pod preamplifiers, and offer minimal noise and crosstalk
(1 Jun, 2010)

C4D Profiler chart extension
A new chart extension for C4D - the C4D Profiler extension for Windows.
(5 May, 2010)

New C4D Data System
The ER225 C4D Data System is designed to be used with eDAQ software packages. It includes PowerChrom software for data collection and analysis.
(25 Feb, 2010)

News Archive

New Software 'C4D Detector' (28 Jan, 2009)
New Baseline Adjust Chart extension (19 Aug, 2008)
Contactless Conductivity Systems (6 Dec, 2007)
Running Multiple Units with PowerChrom (17 Apr, 2006)

Upcoming Events:
 
Special Offers:
 
Recent Hardware Releases:
 
Recent Software Releases:
 
Screencasts:
Chart
C4D for Capillary Electrophoresis and Microchip Electrophoresis
FIA Flow Injection Analysis
Chromatography with PowerChrom
Electrochemistry with EChem and Chart
Electrochemical Impedance Spectroscopy (EIS) with the Z100
Pod-Vu for isoPods
SDx Tethered Membranes

blank
blue blanks