Search results

Jump to: navigation, search

Page title matches

  • ...uivalent protocols using different buffer solutions can also be used, eg 0.1 M KCl, Ringer's solution, [https://en.wikipedia.org/wiki/Saline_(medicine) [[File:tethaPlate6.png|300px|thumb|right|'''Figure 1.''' A tethaPlate. Note the six sample compartments each with a small circul
    7 KB (1,014 words) - 17:31, 18 January 2015

Page text matches

  • ...anic solvent to remove greasy organic materials, or dilute acid or base (0.1 mol/L HCl, HNO<sub>3</sub>, NaOH) to remove inorganics. Protein deposits c ...e electrode at an oxidizing potential (eg +1 V) in dilute acid solution (0.1 mol/L).
    6 KB (1,040 words) - 13:40, 28 April 2017
  • ...Figure 1. SRS QCM200 Quartz Crystal Microbalance.jpg|300px|thumb|'''Figure 1.''' SRS QCM200 Quartz Crystal Microbalance]] ...QCM200 to an e-corder input (See Figure 2), or to ER466 Potentiostat Input 1.
    9 KB (1,432 words) - 20:57, 14 March 2018
  • Typical voltage ranges: 1 uV (thermocouples) to 30,000 volts (capillary electrophoresis high voltage Typical current ranges: <1 pA (small amperometric electrode) to >10 amps (high power potentiostat) - i
    7 KB (1,026 words) - 10:36, 20 May 2016
  • ...of cosmetic cream base with sodium ascorbate.jpg|300px|thumb|right|図 1. 1.0%のアスコルビン酸ソーダ含有の化粧クリームのCV .]] ...有物の抗酸化能を測定しレポートできるます。図1は、1.0%アスコルビン酸ソーダ含有の化粧クリームのボルタ
    3 KB (44 words) - 11:19, 6 June 2014
  • {{#ev:youtube|mbeCoCaTd-Q|300|right|Video 1. How to Setup the EChem Software for Cyclic Voltammetry}} ...molecule of interest must have sufficient solubility (usually more than 0.1 mM) to provide an adequate current signal. Also the solvent should not reac
    41 KB (6,190 words) - 12:28, 31 May 2018
  • [[File:DSC03226-1.JPG|300px|thumb|right|The eDAQ C4D system connected to the Agilent 1600 CE] ...should ensure that the C4D headstage and its flat grey cable are at least 1 cm away from the capillary as it loops inside the cartridge. This is to pre
    5 KB (827 words) - 12:51, 23 January 2019
  • {{#ev:youtube|cvEePW5M180|300|right|Video 1. IV Curve of a Solar Cell}} [[File:Solar cell positive and negative contacts.jpg|300px|thumb|right|Figure 1. Positive and negative contacts on the solar cell]]
    8 KB (1,328 words) - 00:59, 14 November 2014
  • [[File:membranelabelled.png|400px|thumb|right|'''Figure 1.''' Components of a tethered membrane system]] ...ia.org/wiki/Category:Organic_disulfides organic disulfide] anchors, Figure 1. A lipophilic alkane [http://en.wikipedia.org/wiki/Phytane phytanyl group]
    16 KB (2,321 words) - 18:54, 23 August 2013
  • ...ents usually require currents in excess of 10 mA, and a maximum current of 1 A, or more, is often useful if you need to generate a few grams of material | Number of Channels || align="center" | 1 || align="center" | 1 || align="center" | 2 (bipotentiostat) || align="center" | 4 (quadpotentios
    12 KB (1,644 words) - 14:14, 12 February 2020
  • ...h sodium ascorbate.jpg|300px|thumb|right|Figure 1. CV of a cream base with 1.0% sodium ascorbate.]] ...of a given substance. Figure 1 shows the voltammogram of a cream base with 1.0% sodium ascorbate.
    3 KB (435 words) - 10:57, 11 August 2014
  • [[File:DSC01148.JPG|300px|thumb|right|Figure 1. e-corder with PAR362]]
    2 KB (301 words) - 19:15, 23 June 2017
  • * [[File:EAN004_Chart_–_A_Tutorial.pdf]] (1.4 MB PDF) * [[SDx Protocol 1]]
    3 KB (435 words) - 15:27, 5 October 2023
  • [[File:IMG 1229.JPG|300px|thumb|right|Figure 1. eDAQ C4D with Beckman Coulter PA 800plus]] ...rogrammable from the control software. In version 1.2, 1000 mV is equal to 1 absorbance unit (AU) with a fixed 10% negative offset. The high voltage out
    8 KB (1,418 words) - 13:20, 10 October 2019
  • ...should ensure that the C4D headstage and its flat grey cable are at least 1 cm away from the capillary as it loops inside the cartridge. This is to pre ...AD converter built in. It enables voltage conversions ranging from 0 V to 1 V.
    11 KB (1,885 words) - 13:50, 9 March 2020
  • [[File:Peaks of AChCl.jpg|300px|thumb|right|Figure 1. AChCl peaks at different concentrations]] ** lowpass filter = 1 Hz
    2 KB (220 words) - 16:11, 7 January 2014
  • ...on (LOD) is thus 0.3 µM for potassium, calcium, sodium and magnesium, and 1 µM for lithium.
    2 KB (263 words) - 16:21, 7 January 2014
  • [[File:DSC06289.JPG|300px|thumb|right|Figure 1. ET125 Headstage on 1/16th inch tubing after the column]] ''The eDAQ C4D system was connected directly to 1/16th inch tubing for IC/HPLC and used to detect six anions.''
    2 KB (330 words) - 14:08, 23 January 2014
  • [[File:Chip diag.jpg|300px|thumb|right|Figure 1. Chip nomenclature]] ...etection is 3.7 μM for Cl<sup>-</sup> and NO<sub>3</sub><sup>-</sup>, and 1.3 μM for HSO<sub>4</sub><sup>-</sup>.
    2 KB (403 words) - 16:18, 24 August 2016
  • The delta K signal from the C4D Amp was connected to input 1 of the PowerChrom unit. The current monitor was connected to input 2 of the ...ired to reach a current plateau is used to calculate EOF based on Equation 1, where L is the length of the separation channel, V is the total applied vo
    5 KB (834 words) - 12:13, 19 January 2017
  • | [[File:Easy access.jpg|300px|thumb|right|Figure 1. Easy access window]] # In the Easy Access window, shown in Figure 1., click Manual Run.
    7 KB (1,119 words) - 15:47, 31 May 2018

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)