SP100  Zive Potentiostat



SP100 Zive Potentiostat
SP100 Zive Potentiostat
 
  • Solar Cells
  • Supercapacitors
  • Fuel Cells
  • Batteries
  • Sensors
  • General Electrochemistry

 

See the Applications Tab for research citations utilizing the SP100 Potentiostat

 
 
Unit Price: $ (USD) 11990.00

 

This is an economic, high precision potentiostat/galvanostat/impedance analyzer especially designed for electrochemical research with  batteries, fuel cells, corrosion, sensor and solar cells. It is supplied with three software packages:  

  1. BATe control software specific to battery and fuel cell research
  2. CORe control software specific to corrosion related experiments
  3. EIS/EAs control software for general electrochemical experiments.  

 

The ZIVE SP100 electrochemical workstation is ideal for both fundamental research, as well as product development, and quality assurance programs.  This potentiostat excells in the following general categories:

  • new sensors 
  • corrosion/coatings
  • electrode materials
  • membranes
  • conducting polymers
  • battery materials
  • fuel cells
  • supercapacitors
  • photovoltaic materials and solar cells
The ZIVE SP100 operates in the following modes:
  • potentiostat, for voltammetric and chronoamperometric experiments
  • galvanostat
  • ZRA (zero resistance ammeter)
  • FRA (frequency response analyzer) for EIS (electrochemical impedance spectometry)
Analysis software included with the system is the acclaimed ZMAN analysis software.  Please contact your local eDAQ representative to discuss the very large number of analysis features within ZMAN.  

See the brochure for more details.

 

Results Below are from Google Scholar

One-step anodization deposition of anticorrosive bioceramic compounds on AZ31B magnesium alloy for biomedical application

HM Mousa, KH HusseinHM Woo, CH Park… - Ceramics International, 2015 - Elsevier

... 2.4. Potentiodynamic polarization test. Electrochemical tests were carried out using a
ZIVE SP1 potentiostat/galvanostat/EIS device connected to a cell with an SBF solution
controlled at 37±1 °C and a pH value of 7.4. The potentiodynamic ...

Cited by 16 Related articles All 2 versions

 

Co 9 S 8–carbon composite as anode materials with improved Na-storage performance

YN Ko, YC Kang - Carbon, 2015 - Elsevier

... Cyclic voltammograms (CVs) were recorded at a scan rate of 0.1 mV s −1 . Electrochemical
impedance spectra were obtained by AC electrochemical impedance spectroscopy (EIS), using
ZIVE SP1, over a frequency range of 0.01 Hz–100 kHz, using a potential of 10 mV. ...

Cited by 32 Related articles All 2 versions

 

[PDF] thenanoresearch.com

Aerosol-assisted rapid synthesis of SnS-C composite microspheres as anode material for Na-ion batteries

SH Choi, YC Kang - Nano Research, 2015 - Springer

... capacities of this study were based on the total weight of the SnS-C composite.
Electrochemical impedance spectroscopy (EIS) was performed using a ZIVE SP1
over a frequency range of 0.01–100 kHz. 3 Results and discussion ...

Cited by 28 Related articles All 4 versions

 

[PDF] researchgate.net

Growth mechanism and structure of electrochemically synthesized dendritic polymethylsilane molecules

A Mavrič, A Badasyan, G Mali, M Valant - European Polymer Journal, 2017 - Elsevier

... A potential between the Pt reference electrode and the Al cathode was measured with a
potentiostat (ZIVE SP1, WonATech, Seoul, Korea) in an open circuit mode. After the electrolysis
the solvent and volatile compounds were removed under reduced pressure. ...

Cited by 1 Related articles All 4 versions

 

Bi-functionality of mesostructured MnCo 2 O 4 microspheres for supercapacitor and methanol electro-oxidation

GM Thorat, HS JadhavJG Seo - Ceramics International, 2017 - Elsevier

... All the electrochemical tests were carried out on a ZIVE SP1 electrochemical workstation
(Won-A-Tech Co. ... The electro-catalytic activities of the MnCo 2 O 4 electrodes, for the oxidation
of methanol, were investigated on a ZIVE SP1 electrochemical workstation. ...

Cited by 5 Related articles All 3 versions

 

[PDF] researchgate.net

Silver dendrites decorated filter membrane as highly sensitive and reproducible three dimensional surface enhanced Raman scattering substrates

B Zhao, Y Lu, C Zhang, Y Fu, S Moeendarbari… - Applied Surface …, 2016 - Elsevier

... Potentials were applied to the working electrode using ZIVE SP1 potentiostat (Wonatech,
Korea). An Ag/AgCl electrode in 3 M NaCl solution and a platinum mesh were used as the
reference electrode (RE) and the counter electrode (CE), respectively. ...

Cited by 8 Related articles All 5 versions

 

[PDF] researchgate.net

Solution-processed transparent conducting Ag nanowires layer for photoelectric device applications

HS Kim, M Patel, H Kim, JY Kim, MK Kwon, J Kim - Materials Letters, 2015 - Elsevier

... The Mott-Schottky analyses (C–V characteristics) of photoelectric devices were obtained by
applying AC signal (0.1 mV) in the frequency ranges 10–500 kHz by sweeping DC bias range
from −0.6 V to +0.6 V using the Potentiostat/Galvanostat (ZIVE SP1, WonA Tech). ...

Cited by 6 Related articles All 3 versions

 

[HTML] rsc.org

[HTML] Synthesis and electrochemical properties of spherical and hollow-structured NiO aggregates created by combining the Kirkendall effect and Ostwald ripening

JS Cho, JM Won, JH LeeYC Kang - Nanoscale, 2015 - pubs.rsc.org

... 1 cm × 1 cm and the mass loading was approximately 1.2 mg cm −2 . Electrochemical impedance
spectra were obtained by AC electrochemical impedance spectroscopy (EIS) with a ZIVE SP1
over a frequency range of 0.01 Hz–1000 kHz and at a potential amplitude of 10 mV. ...

Cited by 20 Related articles All 6 versions

 

[HTML] rsc.org

Vacuum-process-based dry transfer of active layer with solvent additive for efficient organic photovoltaic devices

JH Lee, KM Kim, W Jang, S Ahn, YY Kim… - Journal of Materials …, 2017 - pubs.rsc.org

... For measurement of impedance of the devices, an impedance analyzer (WonAtech,
Zive SP1) was used. UV-Vis spectrophotometry (Cary 100, Vetiran) was used to obtain
absorption spectra. Impedance measurement was done ...

Cited by 1 Related articles

 

 [HTML] Optical properties and impedance spectroscopy analyses for microscale Si pillar solar cells

M Patel, J Kim - Data in Brief, 2017 - Elsevier

... Subject area, Physics, Electrical Engineering. More specific subject area, Solar cells. Type of
data, Figures, Table. How data was acquired, UV-visible spectrophotometer (UV-2600, Shimadzu),
Potentiostat/Galvanostat (ZIVE SP1, WonA Tech, Korea). Data format, Analyzed. ...

All 3 versions  

 

Effects of brush-anode configurations on performance and electrochemistry of microbial fuel cells

H Kang, J Jeong, PL Gupta, SP Jung - International Journal of Hydrogen …, 2017 - Elsevier

... Measurements of polarization, EIS and CV were performed using a potentiostat/
galvanostat/impedance analyzer (ZIVE SP1, Wonatech, Seoul, South Korea). For
polarization tests, the MFC reactor was operated in open circuit ...

All 3 versions

 

[HTML] sciencedirect.com

[HTML] Sample preparation and electrochemical data of Co 3 O 4 working electrode for seawater splitting

M Patel, WH Park, A Ray, J Kim, JH Lee - Data in Brief, 2017 - Elsevier

... All measurements were done using the three electrode electrochemical cells (Reference electrode:
Ag/AgCl (KCl, 3 M), Counter electrode: platinum gauze, and working electrode: Co 3 O 4
/FTO/glass) attached to the Potentiostat/Galvanostat (PG-stat) (WonA Tech, ZIVE SP1). ...

All 3 versions

 

Electrochemical growth of Co (OH) 2 nanoflakes on Ni foam for methanol electro-oxidation

A Roy, H Jadhav, GM Thorat, JG Seo - New Journal of Chemistry, 2017 - pubs.rsc.org

... Saturated Calomel Electrode (SCE) for 5 minutes at room temperature using a ZIVE SP1
electrochemical workstation (Won-A-Tech Co. LTD, South Korea). The electrodeposited ... electrodes
for methanol oxidation were performed on a ZIVE SP1 electrochemical workstation. ...

 

[PDF] researchgate.net

One-pot synthesis of core–shell-structured tin oxide–carbon composite powders by spray pyrolysis for use as anode materials in Li-ion batteries

YJ HongYC Kang - Carbon, 2015 - Elsevier

... measurements were carried out at a scan rate of 0.1 mV s −1 between 0.001 and 3 V.
Electrochemical impedance spectra of the core–shell-structured tin oxide–carbon composite
powder and the bare SnO 2 powder were analyzed using ZIVE SP1 instrument (Wonatech, Korea ...

Cited by 9 Related articles All 4 versions

 

[HTML] sciencedirect.com

[HTML] Electrical circuit model of ITO/AZO/Ge photodetector

M Patel, J Kim - Data in Brief, 2017 - Elsevier

... Type of data, Figures, Table. How data was acquired, Potentiostat/Galvanostat (ZIVE SP1, WonA
Tech, Korea). Data format, Analyzed. Experimental factors, Impedance spectroscopy: Frequency
range 1 Hz to 20 kHz Bias range → -0.5 V to 0.5 V in step of 0.1 V. ...

All 3 versions

 

[HTML] sciencedirect.com

[HTML] Physical, chemical, and optical data of SnS layers and light switching frequency dependent photoresponses

M Patel, HS Kim, J Kim - Data in Brief, 2017 - Elsevier

... UV-visible diffused reflectance photo spectrometer (Simadzu, UV-2600). Potentiostat/Galvanostat
(ZIVE SP1, WonA Tech, Korea). Data format, Analyzed. Experimental factors, FESEM (Working
distance 10 mm, 15 kV, specimen without conducting coating). ...

All 3 versions

 

[HTML] mdpi.com

[HTML] Effect of laser surface treatment on the corrosion behavior of FeCrAl-coated TZM alloy

JM Kim, TH Ha, JS Park, HG Kim - Metals, 2016 - mdpi.com

... Smartlab, Tokyo, Japan). Electrochemical measurements were performed using a
potentiostat and an electro impedance spectroscopy (EIS) analysis software (ZIVE
SP1, WONATECH, Seoul, Korea). Saturated calomel electrode ...

Cited by 5 Related articles All 6 versions

 

Electrochemical properties of CuO hollow nanopowders prepared from formless Cu–C composite via nanoscale Kirkendall diffusion process

JM Won, JH Kim, YJ Choi, JS Cho, YC Kang - Journal of Alloys and …, 2016 - Elsevier

... voltammograms were measured at a scan rate of 0.07 mV s −1 . Electrochemical impedance
spectra were obtained by AC electrochemical impedance spectroscopy (EIS) with a ZIVE SP1
over a frequency range of 0.01 Hz–100 kHz and at the potential amplitude of 10 mV. ...

Cited by 4 Related articles All 2 versions

 

[PDF] researchgate.net

High potential for the optimum designs for a front contact and junction: A route to heterojunction solar cell

HS Kim, P Yadav, M Patel, H Kim, K Pandey… - Solar Energy Materials …, 2016 - Elsevier

... The Mott-Schottky analysis (1/C 2 –V characteristics) of photoelectric devices were obtained by
applying an AC signal (10 mV) in the frequency range of 10–500 kHz by sweeping the DC bias
from −0.4 V to +0.6 V using the Potentiostat/Galvanostat (ZIVE SP1, WonA Tech). Fig. ...

Cited by 1 Related articles All 4 versions

 

Morphological engineering via processing additive in thin film bulk-heterojunction photovoltaic cells: A systematic understanding of crystal size and charge transport

W Jang, YJ Kim, S Ahn, S Park, CE Park… - Current Applied …, 2016 - Elsevier

... 2.2. Characterization. The performances of the organic solar cells were measured using a solar
simulator, with Air Mass 1.5 Global (AM 1.5 G) at an intensity of 100 mW/cm 2 , and the current
density-voltage characteristics of the solar cells was measured using ZIVE SP1...

Cited by 1 Related articles All 4 versions


 
  • Potential range: ±10V
  • Current ranges: 100 nA, 1, 10, 100 µA, 1, 10, 100 mA, 1 A
  • Current resolution: 16 bits:
  • Current Accuracy:  0.02% f.s
  • Frequency Responce Analyser for EIS: 10 µHz to 1 MHz
  • 12 EIS techniques (including Multi-Sine)
  • Capable of Bipolar Pulse technique
  • Voltage pulse or current pulse charge/discharge test (GSM,CDMA etc.)
  • Ripple simulation available in Battery test package.
  • Pulse plating available
  • Internal 350,000 data point storage
  • Dimendions: 160 x 324 x 76 mm  /  2 kg
  • Includes software packages for:
    - corrosion testing
    - EIS
    - electrochemical analysis
    - battery testing
  • Warranty: 12 months

More Information

SP1_Zive_Potentiostat (1.2 MB PDF)

 Add to Shopping Cart


 

© copyright 2002 - 2024   eDAQ - data recording made simple
       website by frogwebworks
© copyright 2002 - 2024   eDAQ - data recording made simple
website by frogwebworks
© copyright 2002 - 2024 eDAQ - data recording made simple website by frogwebworks
© copyright 2002 - 2024 eDAQ - data recording made simple
website by frogwebworks