SP100 Zive Potentiostat
- Solar Cells
- Supercapacitors
- Fuel Cells
- Batteries
- Sensors
- General Electrochemistry
See the Applications Tab for research citations utilizing the SP100 Potentiostat
This is an economic, high precision potentiostat/galvanostat/impedance analyzer especially designed for electrochemical research with batteries, fuel cells, corrosion, sensor and solar cells. It is supplied with three software packages:
- BATe control software specific to battery and fuel cell research
- CORe control software specific to corrosion related experiments
- EIS/EAs control software for general electrochemical experiments.
The ZIVE SP100 electrochemical workstation is ideal for both fundamental research, as well as product development, and quality assurance programs. This potentiostat excells in the following general categories:
- new sensors
- corrosion/coatings
- electrode materials
- membranes
- conducting polymers
- battery materials
- fuel cells
- supercapacitors
- photovoltaic materials and solar cells
- potentiostat, for voltammetric and chronoamperometric experiments
- galvanostat
- ZRA (zero resistance ammeter)
- FRA (frequency response analyzer) for EIS (electrochemical impedance spectometry)
See the brochure for more details.
Results Below are from Google Scholar
HM Mousa, KH Hussein, HM Woo, CH Park… - Ceramics International, 2015 - Elsevier
... 2.4. Potentiodynamic polarization test. Electrochemical tests were carried out using a
ZIVE SP1 potentiostat/galvanostat/EIS device connected to a cell with an SBF solution
controlled at 37±1 °C and a pH value of 7.4. The potentiodynamic ...
Cited by 16 Related articles All 2 versions
Co 9 S 8–carbon composite as anode materials with improved Na-storage performance
YN Ko, YC Kang - Carbon, 2015 - Elsevier
... Cyclic voltammograms (CVs) were recorded at a scan rate of 0.1 mV s −1 . Electrochemical
impedance spectra were obtained by AC electrochemical impedance spectroscopy (EIS), using
a ZIVE SP1, over a frequency range of 0.01 Hz–100 kHz, using a potential of 10 mV. ...
Cited by 32 Related articles All 2 versions
SH Choi, YC Kang - Nano Research, 2015 - Springer
... capacities of this study were based on the total weight of the SnS-C composite.
Electrochemical impedance spectroscopy (EIS) was performed using a ZIVE SP1
over a frequency range of 0.01–100 kHz. 3 Results and discussion ...
Cited by 28 Related articles All 4 versions
Growth mechanism and structure of electrochemically synthesized dendritic polymethylsilane molecules
A Mavrič, A Badasyan, G Mali, M Valant - European Polymer Journal, 2017 - Elsevier
... A potential between the Pt reference electrode and the Al cathode was measured with a
potentiostat (ZIVE SP1, WonATech, Seoul, Korea) in an open circuit mode. After the electrolysis
the solvent and volatile compounds were removed under reduced pressure. ...
Cited by 1 Related articles All 4 versions
GM Thorat, HS Jadhav, JG Seo - Ceramics International, 2017 - Elsevier
... All the electrochemical tests were carried out on a ZIVE SP1 electrochemical workstation
(Won-A-Tech Co. ... The electro-catalytic activities of the MnCo 2 O 4 electrodes, for the oxidation
of methanol, were investigated on a ZIVE SP1 electrochemical workstation. ...
Cited by 5 Related articles All 3 versions
B Zhao, Y Lu, C Zhang, Y Fu, S Moeendarbari… - Applied Surface …, 2016 - Elsevier
... Potentials were applied to the working electrode using ZIVE SP1 potentiostat (Wonatech,
Korea). An Ag/AgCl electrode in 3 M NaCl solution and a platinum mesh were used as the
reference electrode (RE) and the counter electrode (CE), respectively. ...
Cited by 8 Related articles All 5 versions
Solution-processed transparent conducting Ag nanowires layer for photoelectric device applications
HS Kim, M Patel, H Kim, JY Kim, MK Kwon, J Kim - Materials Letters, 2015 - Elsevier
... The Mott-Schottky analyses (C–V characteristics) of photoelectric devices were obtained by
applying AC signal (0.1 mV) in the frequency ranges 10–500 kHz by sweeping DC bias range
from −0.6 V to +0.6 V using the Potentiostat/Galvanostat (ZIVE SP1, WonA Tech). ...
Cited by 6 Related articles All 3 versions
JS Cho, JM Won, JH Lee, YC Kang - Nanoscale, 2015 - pubs.rsc.org
... 1 cm × 1 cm and the mass loading was approximately 1.2 mg cm −2 . Electrochemical impedance
spectra were obtained by AC electrochemical impedance spectroscopy (EIS) with a ZIVE SP1
over a frequency range of 0.01 Hz–1000 kHz and at a potential amplitude of 10 mV. ...
Cited by 20 Related articles All 6 versions
JH Lee, KM Kim, W Jang, S Ahn, YY Kim… - Journal of Materials …, 2017 - pubs.rsc.org
... For measurement of impedance of the devices, an impedance analyzer (WonAtech,
Zive SP1) was used. UV-Vis spectrophotometry (Cary 100, Vetiran) was used to obtain
absorption spectra. Impedance measurement was done ...
[HTML] Optical properties and impedance spectroscopy analyses for microscale Si pillar solar cells
M Patel, J Kim - Data in Brief, 2017 - Elsevier
... Subject area, Physics, Electrical Engineering. More specific subject area, Solar cells. Type of
data, Figures, Table. How data was acquired, UV-visible spectrophotometer (UV-2600, Shimadzu),
Potentiostat/Galvanostat (ZIVE SP1, WonA Tech, Korea). Data format, Analyzed. ...
Effects of brush-anode configurations on performance and electrochemistry of microbial fuel cells
H Kang, J Jeong, PL Gupta, SP Jung - International Journal of Hydrogen …, 2017 - Elsevier
... Measurements of polarization, EIS and CV were performed using a potentiostat/
galvanostat/impedance analyzer (ZIVE SP1, Wonatech, Seoul, South Korea). For
polarization tests, the MFC reactor was operated in open circuit ...
[HTML] Sample preparation and electrochemical data of Co 3 O 4 working electrode for seawater splitting
M Patel, WH Park, A Ray, J Kim, JH Lee - Data in Brief, 2017 - Elsevier
... All measurements were done using the three electrode electrochemical cells (Reference electrode:
Ag/AgCl (KCl, 3 M), Counter electrode: platinum gauze, and working electrode: Co 3 O 4
/FTO/glass) attached to the Potentiostat/Galvanostat (PG-stat) (WonA Tech, ZIVE SP1). ...
Electrochemical growth of Co (OH) 2 nanoflakes on Ni foam for methanol electro-oxidation
A Roy, H Jadhav, GM Thorat, JG Seo - New Journal of Chemistry, 2017 - pubs.rsc.org
... Saturated Calomel Electrode (SCE) for 5 minutes at room temperature using a ZIVE SP1
electrochemical workstation (Won-A-Tech Co. LTD, South Korea). The electrodeposited ... electrodes
for methanol oxidation were performed on a ZIVE SP1 electrochemical workstation. ...
YJ Hong, YC Kang - Carbon, 2015 - Elsevier
... measurements were carried out at a scan rate of 0.1 mV s −1 between 0.001 and 3 V.
Electrochemical impedance spectra of the core–shell-structured tin oxide–carbon composite
powder and the bare SnO 2 powder were analyzed using ZIVE SP1 instrument (Wonatech, Korea ...
Cited by 9 Related articles All 4 versions
[HTML] Electrical circuit model of ITO/AZO/Ge photodetector
M Patel, J Kim - Data in Brief, 2017 - Elsevier
... Type of data, Figures, Table. How data was acquired, Potentiostat/Galvanostat (ZIVE SP1, WonA
Tech, Korea). Data format, Analyzed. Experimental factors, Impedance spectroscopy: Frequency
range 1 Hz to 20 kHz Bias range → -0.5 V to 0.5 V in step of 0.1 V. ...
M Patel, HS Kim, J Kim - Data in Brief, 2017 - Elsevier
... UV-visible diffused reflectance photo spectrometer (Simadzu, UV-2600). Potentiostat/Galvanostat
(ZIVE SP1, WonA Tech, Korea). Data format, Analyzed. Experimental factors, FESEM (Working
distance 10 mm, 15 kV, specimen without conducting coating). ...
[HTML] Effect of laser surface treatment on the corrosion behavior of FeCrAl-coated TZM alloy
JM Kim, TH Ha, JS Park, HG Kim - Metals, 2016 - mdpi.com
... Smartlab, Tokyo, Japan). Electrochemical measurements were performed using a
potentiostat and an electro impedance spectroscopy (EIS) analysis software (ZIVE
SP1, WONATECH, Seoul, Korea). Saturated calomel electrode ...
Cited by 5 Related articles All 6 versions
JM Won, JH Kim, YJ Choi, JS Cho, YC Kang - Journal of Alloys and …, 2016 - Elsevier
... voltammograms were measured at a scan rate of 0.07 mV s −1 . Electrochemical impedance
spectra were obtained by AC electrochemical impedance spectroscopy (EIS) with a ZIVE SP1
over a frequency range of 0.01 Hz–100 kHz and at the potential amplitude of 10 mV. ...
Cited by 4 Related articles All 2 versions
HS Kim, P Yadav, M Patel, H Kim, K Pandey… - Solar Energy Materials …, 2016 - Elsevier
... The Mott-Schottky analysis (1/C 2 –V characteristics) of photoelectric devices were obtained by
applying an AC signal (10 mV) in the frequency range of 10–500 kHz by sweeping the DC bias
from −0.4 V to +0.6 V using the Potentiostat/Galvanostat (ZIVE SP1, WonA Tech). Fig. ...
Cited by 1 Related articles All 4 versions
W Jang, YJ Kim, S Ahn, S Park, CE Park… - Current Applied …, 2016 - Elsevier
... 2.2. Characterization. The performances of the organic solar cells were measured using a solar
simulator, with Air Mass 1.5 Global (AM 1.5 G) at an intensity of 100 mW/cm 2 , and the current
density-voltage characteristics of the solar cells was measured using ZIVE SP1. ...
- Potential range: ±10V
- Current ranges: 100 nA, 1, 10, 100 µA, 1, 10, 100 mA, 1 A
- Current resolution: 16 bits:
- Current Accuracy: 0.02% f.s
- Frequency Responce Analyser for EIS: 10 µHz to 1 MHz
- 12 EIS techniques (including Multi-Sine)
- Capable of Bipolar Pulse technique
- Voltage pulse or current pulse charge/discharge test (GSM,CDMA etc.)
- Ripple simulation available in Battery test package.
- Pulse plating available
- Internal 350,000 data point storage
- Dimendions: 160 x 324 x 76 mm / 2 kg
-
Includes software packages for:
- corrosion testing
- EIS
- electrochemical analysis
- battery testing - Warranty: 12 months