SP200 Zive SP2 Impedance Potentiostat

SP200 Zive SP2 Impedance Potentiostat
Single Channel High Precision 2A Impedance Potentiostat. Best for:
- Batteries / Supercapacitors
- Fuel Cells
- Corrosion
- Sensors
- Solar Cells
- General EIS experiments
This is a high-precision potentiostat / galvanostat / impedance analyzer, able to work up to 2 amps with 10 volts compliance voltage, designed for high-current electrochemical research with batteries, fuel cells, corrosion, sensor and solar cells. It is supplied with three software packages:
- BATe control software specific to battery and fuel cell research
- CORe control software specific to corrosion related experiments
- EIS/EAs control software for general electrochemical experiments.
The ZIVE SP200 electrochemical workstation is ideal for both fundamental research, as well as product development, and quality assurance programs. This potentiostat excels in the following general categories:
- new sensors
- corrosion/coatings
- electrode materials
- membranes
- conducting polymers
- battery materials
- fuel cells
- supercapacitors
- photovoltaic materials and solar cells
The ZIVE SP200 operates in the following modes:
- potentiostat, for voltammetric and chronoamperometric experiments
- galvanostat
- ZRA (zero resistance ammeter)
- FRA (frequency response analyzer) for EIS (Electrochemical Impedance Spectroscopy)
Analysis software included with the system is the acclaimed ZMAN analysis software. Please contact your local eDAQ representative to discuss the very large number of analysis features within ZMAN.
See the brochure for more details.
MJ Hwang, EJ Park, WJ Moon, HJ Song, YJ Park - Corrosion Science, 2015 - Elsevier
... Institute Gwangju Center, Gwangju 500-757, Republic of Korea. Received 23 September 2014,
Accepted 4 April 2015, Available online 20 April ... over the frequency range from 10 6 to 0.01 Hz
with amplitude of 10 mV using an impedance analyzer (ZIVE SP2, WonA Tech Co., Ltd ...
Cited by 10 Related articles All 2 versions
J Park, WG Moon, GP Kim, I Nam, S Park, Y Kim, J Yi - Electrochimica Acta, 2013 - Elsevier
... 139-701, Republic of Korea. Received 28 March 2013, Revised 18 April 2013, Accepted 22 April
2013, Available online 13 May ... Electrochemical impedance spectroscopy (EIS, ZIVE SP2,
Wonatech) measurements were performed over a frequency rate of 200 kHz to 10 mHz at ...
Cited by 25 Related articles All 9 versions
T Kim, J Shin, TS You, H Lee, J Kim - Electrochimica Acta, 2015 - Elsevier
... Received 17 November 2014, Revised 6 February 2015, Accepted 25 February 2015, Available
online 26 February 2015. ... at a scan rate of 1 mV s −1 over the voltage range 4.0–2.1 V.
Electrochemical impedance spectra (EIS) were obtained using WonATech ZIVE SP2 at a ...
Cited by 12 Related articles All 4 versions
J Shin, H Jung, Y Kim, J Kim - Journal of Alloys and Compounds, 2014 - Elsevier
... Busan 604-714, South Korea. Received 30 August 2013, Revised 1 October 2013, Accepted
28 November 2013, Available online 4 December ... test system at a scan rate of 0.1 mV s −1 .
Electrochemical impedance spectra (EIS) were obtained using a WonATech ZIVE SP2 at a ...
Cited by 25 Related articles All 5 versions
GP Kim, S Park, I Nam, J Park, J Yi - Journal of Power Sources, 2013 - Elsevier
... Received 21 January 2013, Revised 26 February 2013, Accepted 1 March 2013, Available online
21 March 2013. ... 718 mA g −1 (1 C). The electrochemical impedance spectroscopy (EIS) of the
electrode was performed on an electrochemical workstation (WonA tech, ZIVE SP2). ...
Cited by 28 Related articles All 7 versions
J Shin, T Kim, J Je, TS You, J Kim - Electrochimica Acta, 2014 - Elsevier
... Cheongju, Chungbuk 361-763 South Korea. Received 19 May 2014, Revised 24 June 2014,
Accepted 1 July 2014, Available online 17 July ... 0.1 mV s −1 over the voltage range 4.0–2.1 V.
Electrochemical impedance spectra (EIS) were obtained using a WonATech ZIVE SP2 at a ...
Cited by 6 Related articles All 6 versions
Y Jung, YC Jeong, JH Kim, YS Kim, T Kim… - Energy Storage …, 2016 - Elsevier
... Received 31 March 2016, Revised 17 May 2016, Accepted 18 May 2016, Available online 19
May 2016. ... Electrochemical impedance spectra were characterized using a potentiostat (ZIVE
SP2, WonATech) at an open circuit voltage with AC amplitude at 5 mV in the 10 mHz to ...
MK Han, MJ Hwang, MS Yang, HS Yang… - Materials Science and …, 2014 - Elsevier
... 500-757, Republic of Korea. Received 7 March 2014, Revised 14 July 2014, Accepted 5 August
2014, Available online 12 August ... of the various Ti–xZr/cp-Ti galvanic pairs were measured over
a 20 min period by using Potentiostat/Galvanostat (ZIVE SP2, WonA Tech Co., Korea ...
Cited by 15 Related articles All 5 versions
Structural and optical properties of ZnS thin film grown by pulsed electrodeposition
H Hennayaka, HS Lee - Thin Solid Films, 2013 - Elsevier
... Received 4 April 2013, Revised 3 September 2013, Accepted 4 September 2013, Available online
11 September 2013. ... method was applied with a V on of − 1.2 V versus SCE for 10 s and V off
of − 0.8 V versus SCE for 5 s using the Potentiostat (ZIVE SP2, WonA Tech, Korea). ...
Cited by 23 Related articles All 7 versions
SK Jung, H Gwon, J Hong, KY Park… - Advanced Energy …, 2014 - Wiley Online Library
... electrochemical impedance spectroscopy (EIS) measurements were performed on the tested
cells using an impedance analyzer (ZIVE SP2; WonA Tech) at room ... Issue online: 6 January 2014;
Version of record online: 21 August 2013; Manuscript Received: 8 July 2013. ...
Cited by 204 Related articles All 5 versions
H Jung, H Song, T Kim, JK Lee, J Kim - Journal of Alloys and Compounds, 2015 - Elsevier
... A University, Busan 604-714, South Korea. Received 4 April 2015, Revised 1 June 2015, Accepted
22 June 2015, Available online 25 June ... of 3.3 V in the frequency range of 10 -2 –10 5 Hz with
a 10 mV AC signal by a ZIVE SP2 impedance analyzer (WonATech). ...
Cited by 16 Related articles All 3 versions
GP Kim, I Nam, S Park, J Park, J Yi - Nanotechnology, 2013 - iopscience.iop.org
... The electrodeposition was performed at room temperature using the WPG100 electrochemical
workstation (WonAtech) with a three-electrode system. ... was performed on a battery tester (WonA
tech, WBCS3000) and an electrochemical workstation (WonA tech, ZIVE SP2) using a ...
Cited by 10 Related articles All 9 versions
YS Yun, YH Kim, MY Song, NR Kim, K Ku, JS An… - Journal of Power …, 2016 - Elsevier
... 751, South Korea. Received 20 November 2015, Revised 5 September 2016, Accepted 16
September 2016, Available online 23 September ... impedance spectroscopy (EIS) measurements
were performed on the cells using an impedance analyzer (ZIVE SP2; Wonatec) at room ...
Cited by 5 Related articles All 4 versions
TH Choi, YB Won, JW Lee, DW Shin, YM Lee… - Journal of Power …, 2012 - Elsevier
... 24 April 2012, Revised 17 June 2012, Accepted 31 July 2012, Available online 8 August ... on the
membrane surfaces were stained with bacterial viability kit (L7012, Live/Dead BacLight ... from an
open circuit voltage (OCV) to +0.2 V using a workstation (Zive SP2, Wonatech, Korea ...
Cited by 34 Related articles All 9 versions
Investigation of passivation and galvanic corrosion of Ti–Nb alloys and pure titanium
MJ Hwang, HR Choi, MS Kook, HJ Song… - Materials and …, 2015 - Wiley Online Library
... The galvanic performance of the Ti–Nb alloys was investigated using a galvanostat
(ZIVE SP2, WonA Tech Co., Ltd.) and their current densities were recorded for 20 min.
3 Results and discussion. 3.1 Open circuit potential (OCP). ...
Cited by 1 Related articles All 2 versions
H Kim, MY Cho, MH Kim, KY Park… - Advanced Energy …, 2013 - Wiley Online Library
... Electrochemical impedance spectroscopy (EIS) was performed using a ZIVE SP2
electrochemical workstation (WonATech). ... Supporting Information. Supporting Information is
available from the Wiley Online Library or from the author. Acknowledgements. ...
Cited by 147 Related articles All 2 versions
[PDF] Electrochemical and Mechanical Properties of Cast Ti-V Alloys for Dental Applications
KH Park, MJ Hwang, HJ Song, YJ Park - Int. J. Electrochem. Sci, 2016 - electrochemsci.org
... [14]. The AC impedance spectra were obtained in the frequency range of 10 5 to 0.01 Hz with
an amplitude of 10mV, using a ZIVE SP2 instrument (WonA Tech., Korea). The optimized
equivalent circuit was obtained by a non‐linear least-squares fitting. ...
Related articles All 3 versions Cite
T Kim, WJ Jae, H Kim, M Park, JM Han… - Journal of Materials …, 2016 - pubs.rsc.org
... Specific capacities were calculated based on the total mass of FeF 3 /carbon composites
Electrochemical impedance spectra (EIS) were obtained at a charged potential of 4.5 V on a
ZIVE SP2 (WonATech), utilizing a frequency range of 10 −2 to 10 5 Hz and a 10 mV amplitude ...
Hierarchically nanoporous pyropolymer nanofibers for surface-induced sodium-ion storage
HJ Yoon, ME Lee, NR Kim, SJ Yang, HJ Jin, YS Yun - Electrochimica Acta, 2017 - Elsevier
... Received 22 February 2017, Revised 12 April 2017, Accepted 2 May 2017, Available online
3 May 2017. ... impedance spectroscopy (EIS) tests were performed at room temperature in the
frequency range of 100 kHz to 0.1 Hz using an impedance analyzer (ZIVE SP2, WonATech). ...
Cited by 1 Related articles All 2 versions
B Ding, L Shen, G Xu, P Nie, X Zhang - Electrochimica Acta, 2013 - Elsevier
... 23 March 2013, Revised 2 June 2013, Accepted 8 June 2013, Available online 12 June ... cyclic
voltammograms (CV) and electrochemical impedance spectroscopy (EIS) measurement were
conducted with a Zive SP2 electrochemical workstation (WonATech Co. ...
Cited by 59 Related articles All 5 versions
- high quality potentiostat/galvanostat/impedance analyzer
- ±10V@2Amp control range
-
current range (12 ranges)
- 2A to 20pA
- 20pA & 200pA with gain - frequency range : 10uHz ~ 2MHz
- built-in FRA : enables EIS tests
- 14 EIS techniques capability including multisine
-
capable of multitude of applications
- corrosion, general electrochemistry, sensor, battery, fuel cell,
supercapacitor, solar cell, etc. - bipolar pulse capability
- voltage pulse or current pulse charge/discharge test(GSM,CDMA etc.), sine wave function for ripple simulation in battery test package & pulse plating available
-
high speed data sampling time
- 50usec/sample in burst mode
- 1msec/sample in normal mode
- 2usec/sample in fast sweep mode - fast sweep mode(5000V/sec with 10mV data sampling)
- iR compensation & measurement
- 3 measurement/control voltage ranges & 12 measurement/control current ranges
- internal 295,000 data point storage & continuing experiment regardless of PC failure.
- LCD display
-
software package
- Corrosion software package
- EIS software package
- Electrochemical analysis software package
- Energy software package - multichannel configuration available by connecting multiple SP2 or other ZIVE products
- power booster (ZIVE ZB series) available
- includes basic software, Energy/Impedance/Battery/Echem analysis software packages
- free software upgrade